top of page

CTE & TRADES · POSTSECONDARY CTE, APPRENTICESHIP, COLLEGE · 50 MINUTES

The Tenant Test Fit: Usable Area, Workstations and Density lesson plan

Commercial real estate, architecture and interior-design students test-fit an office suite on a full-size print: rentable to usable area, offices and rooms first, then how many workstations really fit.

Free, no sign-up, and no print needed. A life-size floor print is optional: school prints are $0.45 per printed sq ft, $100 minimum.

On this page: Teach it in 5 steps · Learner card · Printable

Classroom setup sketch for The Tenant Test Fit (Usable Area, Workstations and Density), showing the room layout, tape lines and team spots

At a glance

  • Time: 50 minutes

  • Level: Postsecondary CTE, apprenticeship, college

  • Subject: CTE & trades: Usable Area, Workstations and Density

  • Grouping: Teams of 3: broker, designer, tenant.

  • Space: A classroom floor for the two taped modules.

  • Included: Teacher script, scenario sheet, learner sheet, exit ticket and answer key with every number worked

Open the printable lesson: script, scenario, learner sheet and answer key (PDF) →


Teach it in 5 steps

The whole lesson on one screen. Details for each step are further down.

  1. Before class: Tape one 6 x 6 ft workstation and a 10 x 12 ft office so students feel the sizes.

  2. Show them (5 min): Hook. "6,000 sq ft. They want 80 seats. Easy?"

  3. Try it together (10 min): Usable area. Divide rentable by the 1.15 load factor.

  4. Teams work (30 min): Run steps 3-5 of the procedure below: Rooms first → Workstations → Answer the tenant.

  5. Check (5 min): Exit ticket: 4,600 RSF at a 1.15 load factor. Usable?


Learner card

Read this part with your class, or print it for each team.

Your challenge
The tenant says they need 80 seats in this 6,000 sq ft suite. Run the test fit and tell the broker what really fits.

By the end, I can:

  • convert rentable to usable area with a load factor

  • take rooms out first and fit workstations in what is left

  • report seats, square feet per person and seats per 1,000 sq ft

Who uses this
tenant-rep brokers, workplace strategists, interior designers and architects, who run test fits before a lease is signed.


Essential question

How many people really fit in a space, and who finds out before the lease is signed?


What learners learn and show

  • The big idea: A test fit starts from usable, not rentable, area; rooms come first, and every workstation carries circulation with it.

  • Show it: a test-fit sheet with usable area, room totals, the workstation count, density figures and an answer to the 80-seat ask.

Objectives

  • Divide rentable area by the load factor.

  • Subtract offices, conference rooms and support.

  • Divide what is left by a workstation plus circulation.

  • Report density and answer the tenant.


Materials and prep

  • A 1:1 print of one workstation bay and an office, or both taped

  • Calculators

  • The printable: scenario sheet and test-fit sheet

Prep

  1. Tape one 6 x 6 ft workstation and a 10 x 12 ft office so students feel the sizes.

  2. Print one test-fit sheet per team.

Space: A classroom floor for the two taped modules.

Grouping: Teams of 3: broker, designer, tenant.


Lesson procedure

  1. 0-5 min, Hook: "6,000 sq ft. They want 80 seats. Easy?" Ask: What do you need to know first? Listen for: How much of the space is usable.

  2. 5-15 min, Usable area: Divide rentable by the 1.15 load factor. Ask: Usable? Listen for: 5,217 sq ft.

  3. 15-25 min, Rooms first: Subtract 6 offices, 2 conference rooms and support. Ask: What is left? Listen for: 3,497 sq ft.

  4. 25-38 min, Workstations: Stand in the taped 6 x 6. Divide what is left by 36 sq ft plus 35% circulation. Ask: How many fit? Listen for: 71 workstations.

  5. 38-45 min, Answer the tenant: Total seats, square feet per person, seats per 1,000. Ask: Do 80 seats fit? Listen for: No: 77 seats.

  6. 45-50 min, Exit ticket: Individual exit ticket.


Checks for understanding

  • Ask: Why divide by the load factor? Look for: Rentable area includes a share of lobbies and corridors the tenant can't furnish.

  • Ask: Why add circulation to each workstation? Look for: People need aisles to reach their desks.

  • Ask: Why place rooms before desks? Look for: Rooms are fixed needs; desks fill what remains.


Exit ticket

  1. 4,600 RSF at a 1.15 load factor. Usable? Answer: 4,000 sq ft.

  2. 1,944 sq ft left at 48.6 sq ft per workstation? Answer: 40 workstations.

  3. 50 people in 4,000 usable sq ft. Seats per 1,000? Answer: 12.5.

Scoring: 1 point each, plus 1 for the tenant answer with numbers. 3 or more = secure.


Common misconceptions

  • Learners may think: Seats = rentable area / desk size. Address it: That skips the load factor, the rooms and the circulation.

  • Learners may think: Circulation is wasted space. Address it: Without it nobody can reach a desk.


Supports and extensions

Give a filled example row.

Multilingual learners: label rentable, usable, circulation and workstation with icons.

Mobility: the taped modules can be judged from a seat.

Transfer task: Test-fit your classroom or studio as an office and report seats and density.


Why at full scale

Standing inside a taped 6 x 6 with its aisle shows why circulation is real floor.


Codes, standards and frameworks

Codes and standards change and are adopted locally. This lesson teaches the method; use the edition your jurisdiction or program has adopted.


Ready to teach it?

The printable has the teacher script, the scenario sheet, the learner sheet and the answer key. Open the printable lesson →

Need the floor plan itself? Get a 1:1 print quote.


Paying for the print? Use a grant

Many teachers fund the 1:1 print with Perkins V career and technical education funds. Start from From Drawing to Takeoff: a construction-trades pathway on life-size plans, our grades 9-12 CTE grant packet, and add this lesson to its timetable. The packet has a project description, measurable objectives, a lesson timetable, an evaluation plan, a budget and a principal letter, written to the questions funders ask.

Download the grant packet (PDF) · Editable Word version · All funding options


Related lessons

More in the College & Trades track: The MacLeamy Curve · The Pre-Pour Walk · The Slab Takeoff · Square the Layout · Receptacle Layout to Code · Measure It Like an Appraiser · Walk the Patient Room · The Owner Walk · Equipment Footprints and Service Clearances · Space Planning Review · Occupant Load and Exits · Plan the Sales Floor · Set the Banquet Room · The Site Logistics Plan · Walk the Kitchen Line · Check the Toilet Room · Lab Safety Layout · Lay Out the Stair · Place the Smoke Alarms · Plan the Child Care Room · Rack the Warehouse · Lay Out the Parking Lot · Roof Takeoff from the Plan · Space the Sprinkler Heads · Lay Out the Tile

Browse all 100 floor plan lesson plans · Standards map

bottom of page